Stålrørledninger og stålrør til spesielle formål

Komité: ECISS/TC 103 (Structural steels other than reinforcements)
Opprinnelse:
Sluttdato: 25. okt 2018
Vis merVis mindre
 
This document specifies tolerances for cold formed welded circular, square, rectangular and elliptical structural hollow sections, manufactured in wall thicknesses up to 40 mm, in the following size ranges: - Circular: Outside diameters up to 2 500 mm; - Square: Outside dimensions up to 500 mm × 500 mm; - Rectangular: Outside dimensions up to 500 mm × 300 mm; - Elliptical: Outside dimensions up to 480 mm × 240 mm. The formulae for calculating sectional properties of sections manufactured to the dimensional tolerances of this standard, to be used for the purposes of structural design, are given in Annex A. Dimensions and sectional properties for a limited range of more common sizes are given in Annex B. NOTE The designation of the sections' major axis (yy) and its minor axis (zz) align with the axis designation used for structural design in the structural Eurocodes.